Difference between revisions of "Osgeo6"
Jump to navigation
Jump to search
(Removed redirect to Mail server) Tag: Removed redirect |
|||
| Line 1: | Line 1: | ||
The host is reachable by ssh at '''osgeo6.osgeo.osuosl.org'''. | The host is reachable by ssh at '''osgeo6.osgeo.osuosl.org'''. | ||
| − | Used to be the [[Mail server]] but as of | + | Used to be the [[Mail server]] but as of March 2026 its been reformatted to be incus host. |
= Hardware = | = Hardware = | ||
| Line 23: | Line 23: | ||
3 year warranty starting on May 4,2015 ending on May 4,2018 | 3 year warranty starting on May 4,2015 ending on May 4,2018 | ||
| + | Disks were replaced March 2026 with 5 SSD | ||
| + | <pre> | ||
| + | NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINTS | ||
| + | sda 8:0 0 1.8T 0 disk | ||
| + | └─sda1 8:1 0 1.8T 0 part | ||
| + | └─md1 9:1 0 7.3T 0 raid5 | ||
| + | ├─osgeo6-swap 253:0 0 29.8G 0 lvm [SWAP] | ||
| + | ├─osgeo6-root 253:1 0 186.3G 0 lvm / | ||
| + | └─osgeo6-incus_zfs 253:2 0 4T 0 lvm | ||
| + | sdb 8:16 0 1.8T 0 disk | ||
| + | └─sdb1 8:17 0 1.8T 0 part | ||
| + | └─md1 9:1 0 7.3T 0 raid5 | ||
| + | ├─osgeo6-swap 253:0 0 29.8G 0 lvm [SWAP] | ||
| + | ├─osgeo6-root 253:1 0 186.3G 0 lvm / | ||
| + | └─osgeo6-incus_zfs 253:2 0 4T 0 lvm | ||
| + | sdc 8:32 0 1.8T 0 disk | ||
| + | ├─sdc1 8:33 0 1G 0 part /boot/efi | ||
| + | ├─sdc2 8:34 0 1G 0 part | ||
| + | │ └─md0 9:0 0 1022M 0 raid1 /boot | ||
| + | └─sdc3 8:35 0 1.8T 0 part | ||
| + | └─md1 9:1 0 7.3T 0 raid5 | ||
| + | ├─osgeo6-swap 253:0 0 29.8G 0 lvm [SWAP] | ||
| + | ├─osgeo6-root 253:1 0 186.3G 0 lvm / | ||
| + | └─osgeo6-incus_zfs 253:2 0 4T 0 lvm | ||
| + | sdd 8:48 0 1.8T 0 disk | ||
| + | sde 8:64 0 1.8T 0 disk | ||
| + | └─sde1 8:65 0 1.8T 0 part | ||
| + | └─md1 9:1 0 7.3T 0 raid5 | ||
| + | ├─osgeo6-swap 253:0 0 29.8G 0 lvm [SWAP] | ||
| + | ├─osgeo6-root 253:1 0 186.3G 0 lvm / | ||
| + | └─osgeo6-incus_zfs 253:2 0 4T 0 lvm | ||
| + | sdf 8:80 0 1.8T 0 disk | ||
| + | ├─sdf1 8:81 0 1G 0 part | ||
| + | ├─sdf2 8:82 0 1G 0 part | ||
| + | │ └─md0 9:0 0 1022M 0 raid1 /boot | ||
| + | └─sdf3 8:83 0 1.8T 0 part | ||
| + | └─md1 9:1 0 7.3T 0 raid5 | ||
| + | ├─osgeo6-swap 253:0 0 29.8G 0 lvm [SWAP] | ||
| + | ├─osgeo6-root 253:1 0 186.3G 0 lvm / | ||
| + | └─osgeo6-incus_zfs 253:2 0 4T 0 lvm | ||
| + | </pre> | ||
[[Category:Infrastructure]] | [[Category:Infrastructure]] | ||
Revision as of 23:11, 12 March 2026
The host is reachable by ssh at osgeo6.osgeo.osuosl.org.
Used to be the Mail server but as of March 2026 its been reformatted to be incus host.
Hardware
Details:
CPU: 2 x Intel Xeon E5-2620v3, 2.4 GHz (6-Core, HT, 15MB Cache, 85W) 22nm RAM: 128GB (8 x 16GB DDR4-2133 ECC Registered 2R 1.2V DIMMs) Operating at 2133 MT/s Max NIC: Dual Intel i210 Gigabit Ethernet Controllers - Integrated Management: Integrated IPMI 2.0 & KVM over LAN Controller: 10 Ports 6Gb/s SATA (Intel C612 Chipset) PCIe 3.0 x8: No Item Selected NOTE: Hot-swap and fixed drives will be connected to SATA3 controller (C612) unless otherwise specified Hot-Swap Drive - 1: 80GB Intel DC S3500 Series MLC (6Gb/s, 0.3 DWPD) 2.5" SATA SSD Hot-Swap Drive - 2: 80GB Intel DC S3500 Series MLC (6Gb/s, 0.3 DWPD) 2.5" SATA SSD Hot-Swap Drive - 3: 480GB Intel DC S3500 Series MLC (6Gb/s, 0.3 DWPD) 2.5" SATA SSD Hot-Swap Drive - 4: 480GB Intel DC S3500 Series MLC (6Gb/s, 0.3 DWPD) 2.5" SATA SSD Hot-Swap Drive - 5: 480GB Intel DC S3500 Series MLC (6Gb/s, 0.3 DWPD) 2.5" SATA SSD Hot-Swap Drive - 6: 480GB Intel DC S3500 Series MLC (6Gb/s, 0.3 DWPD) 2.5" SATA SSD Optical Drive: No Item Selected
3 year warranty starting on May 4,2015 ending on May 4,2018
Disks were replaced March 2026 with 5 SSD
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINTS sda 8:0 0 1.8T 0 disk └─sda1 8:1 0 1.8T 0 part └─md1 9:1 0 7.3T 0 raid5 ├─osgeo6-swap 253:0 0 29.8G 0 lvm [SWAP] ├─osgeo6-root 253:1 0 186.3G 0 lvm / └─osgeo6-incus_zfs 253:2 0 4T 0 lvm sdb 8:16 0 1.8T 0 disk └─sdb1 8:17 0 1.8T 0 part └─md1 9:1 0 7.3T 0 raid5 ├─osgeo6-swap 253:0 0 29.8G 0 lvm [SWAP] ├─osgeo6-root 253:1 0 186.3G 0 lvm / └─osgeo6-incus_zfs 253:2 0 4T 0 lvm sdc 8:32 0 1.8T 0 disk ├─sdc1 8:33 0 1G 0 part /boot/efi ├─sdc2 8:34 0 1G 0 part │ └─md0 9:0 0 1022M 0 raid1 /boot └─sdc3 8:35 0 1.8T 0 part └─md1 9:1 0 7.3T 0 raid5 ├─osgeo6-swap 253:0 0 29.8G 0 lvm [SWAP] ├─osgeo6-root 253:1 0 186.3G 0 lvm / └─osgeo6-incus_zfs 253:2 0 4T 0 lvm sdd 8:48 0 1.8T 0 disk sde 8:64 0 1.8T 0 disk └─sde1 8:65 0 1.8T 0 part └─md1 9:1 0 7.3T 0 raid5 ├─osgeo6-swap 253:0 0 29.8G 0 lvm [SWAP] ├─osgeo6-root 253:1 0 186.3G 0 lvm / └─osgeo6-incus_zfs 253:2 0 4T 0 lvm sdf 8:80 0 1.8T 0 disk ├─sdf1 8:81 0 1G 0 part ├─sdf2 8:82 0 1G 0 part │ └─md0 9:0 0 1022M 0 raid1 /boot └─sdf3 8:83 0 1.8T 0 part └─md1 9:1 0 7.3T 0 raid5 ├─osgeo6-swap 253:0 0 29.8G 0 lvm [SWAP] ├─osgeo6-root 253:1 0 186.3G 0 lvm / └─osgeo6-incus_zfs 253:2 0 4T 0 lvm